VELFAC Classic windows, Commercial structural interface drawings

The structural interface drawings feature VELFAC Ribo wood/aluminium, but VELFAC Classic wood/aluminium and VELFAC Classic wood are installed according to the same methods.
Timber Cladding - Block Masonry - Head
Timber as outer skin of structure
Brick - Block Masonry - Head
Brick as outer skin of structure
Insulated Render - Block Masonry - Head
Insulated Render as outer skin of structure
Rendered Block - Block Masonry - Head
Rendered Block as outer skin of structure

Outward opening VELFAC Classic wood/aluminium doors (Commercial projects)

Brick - Block Masonry - Head
Brick as outer skin of structure
Insulated Render - Block masonry - Head
Insulated Render as outer skin of structure
Rendered Block - Block Masonry - Head
Rendered Block as outer skin of structure
Timber - Block Masonry - Head
Timber as outer skin of structure
Threshold Detail (RIBO.D1.01.A.C.001)
Threshold Details
Typical Coping Interface detail (V200.W1.COP.001)
Coping Interface details

Inward opening VELFAC Classic wood/aluminium doors (Commercial projects)

Brick - Timber Frame - Head
Brick as outer skin of structure
Insulated Render - Block masonry - Head
Insulated Render as outer skin of structure
Rendered Block - Block Masonry - Head
Rendered Block as outer skin of structure
Timber - Block Masonry - Head
Timber as outer skin of structure
Threshold Detail (RIBO.D2.01.A.C.001)
Threshold Details
Typical Coping Interface detail (V200.W1.COP.001)
Coping Interface details